Programming a new Master Code.

To program a new Master code, enter (*)(5)(master code)(40)(new code). The new code must be a four digit number. Use digits 0 through 9 only. Press (#) to return to the READY state.

EXAMPLE:     *,5,Master code,40,4321,#. Test the new code.

"Always test your code by turning the system on and off with it."

Programming codes from a LCD/LED keypad.

To erase, add or change a user code, enter (*)(5)(master code) (code number 01 to 32)(new code). The new code must be a four digit number. Use digits 0 through 9 only. Press (#) to return to the READY state.

EXAMPLE:     *,5,Master Code,02,4321,#. Test the new code.

To delete a user code, enter (*)(5)(Master Code) (Code number 01 to 32)(*)(#).

 

Setting the Time and Date:

To set the system time, enter (*)(6)(Master Code)(1). The keypad will now accept ten consecutive digits:

    Enter the Time in - Hours and Minutes using the 24 hour format (00:00 to 23:59).

    Enter the Date in - Month, Day, and Year (MMDDYY).

    Press (#) to return to the READY state.

EXAMPLE:     *,6,Master Code,1,(00:00 to 23:59),MMDDYY,#

 

Zone Bypassing

The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones that are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made.

Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed.

Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied before the next arming.

Bypassing zones reduces your security protection. If you are bypassing a zone due to damaged wiring or contacts, please call a service technician immediately so that the problem can be resolved and your system returned to proper working order.

Make sure that no zones are unintentionally bypassed when arming your system.

To bypass zones from an LED/LCD keypad:

Start with the system in the Ready state. Enter [*][1][Zone(s) to be bypassed].

Enter the zone(s) as a 2-digit number from 01 to 32. As each zone is bypassed, the corresponding zone light will turn ON. If a zone is bypassed by mistake, enter that zone number again; the zone light will turn OFF, indicating that the zone is not bypassed. Press [#] to return to the Ready state.

EXAMPLE:   *,1,(00 to 32),#    or

                      *,1,Master Code,(00 to 32),#


Trouble Messages:

To view the type of trouble condition, press (*)(2). One or more zone lights corresponding to the following system troubles will turn on,

Zone Light

   1         Service required, Press (1) and one or more of the zones lights          corresponding to the following will turn on.                       

                    1. LOW BATTERY

                    2. BELL CIRCUIT TROUBLE

                    3. GENERAL SYSTEM TROUBLE

                    4. GENERAL SYSTEM TAMPER

                    5. GENERAL SYSTEM SUPERVISORY

         2          Indicates the loss of AC power. 

         3         Telephone line trouble

         4         The panel has failed to communicate with the monitoring center.

       5         Zone fault. Press (5) and the zone light (s) corresponding to the   faulted

   zones will turn ON.                                                             

6          Zone tamper. press (6) and the zone light (s) corresponding to the

tampered zones will turn ON.                                     

         7         Device Low Battery: Press (7) one, two or three times to view        which devices are experiencing battery failure.                

          8           Loss of Time. Clock needs to be reset it. (follow above procedures)

 